Proguard RR Gloves Leaded

The Proguard RX and Proguard LFX radiation attenuating gloves are intended to reduce the amount of scattered radiation exposure to the hands during fluoroscopic procedures. Proguard radiation attenuating gloves are the preferred choice for doctors in the following vocations: Radiology, Cath/EP Lab, Orthopedics, Endoscopy, Urological Procedures, Special Procedures, and Pain Management.

Price is for 1 box (5 pairs)

The Proguard RX and Proguard LFX radiation attenuating gloves are intended to reduce the amount of scattered radiation exposure to the hands during fluoroscopic procedures. Proguard radiation attenuating gloves are the preferred choice for doctors in the following vocations: Radiology, Cath/EP Lab, Orthopedics, Endoscopy, Urological Procedures, Special Procedures, and Pain Management.

Price is for 1 box (5 pairs)

  • Allergens: Latex Free and Powder Free
  • Internal Slipcoat: Polymer Coated
  • Sterility: Sterilized by Ethylene Oxide
  • Post Processing: Polymer Rinsing
  • Shelf Life: 3 Years as per ASTM 7160-05
  • Glove Design: Hand Specific
  • Cuff: Non-beaded
  • Glove Length: 280mm (minimum)

Packaging:Pouch (1 Pair); Box (5 Pairs); Carton (20 Pairs)

Certified to ASTM 2547 and IEC 61331-1:2014 Standards

 

Lead

Storage, Disposal and Expiration

Storage:

Store product in a cool dry area. Keep out of direct sunlight. Avoid sharp objects, damage will allow radiation to pass through.

Click Here For More Information For Storage & Care

Disposal:

Lead Based Products contains lead and should be disposed of through hazardous waste procedures in accordance with local laws and regulations. The material should not be disposed of by incineration and if material catches fire in any way, please ensure that you are using a self-containing breathing apparatus.

Zero Lead is a lead-free material that is not “cross-linked” (or “cured”) and is therefore fully recyclable, and thermally re-processable, or may be disposed of as a non-hazardous, non-toxic waste, in municipal landfills.

Click Here For More Information for Disposal

Expiration:

This is a sterilized product and expiration is set at 3 years from manufactured date per FDA requirement. his Indication may be found on the label on the original external packaging and indicates the period of time during which the device, sterilized with Ethylene Oxide, may be used as long as it has been stored properly in suitable conditions and has intact packaging.

Intended Use

Intended Use: To protect the user’s hands from scattered secondary radiation originating from the X-ray beam during fluoroscopic procedures by providing an attenuating barrier to radiation. They are not intended for use in direct or primary X-ray beams. They are also not intended to protect from abrasions, cuts, tears, punctures, and heat/fire. The RR gloves are ideal where the user needs excellent dexterity combined with protection from ionizing radiation during various types of procedures such as General X-Ray & Fluoroscopy, Radiography, Neurology, Urology, MRI, CT, Radiotherapy and Nuclear Medicine.

Compliance Requirements: ASTM D5151, ASTM D6124, ASTM D412, ASTM F2547, EN ISO 374-1:2016, EN ISO 374-5:2016, EN 421:2010 (excl. clause 4.3) EN 420:2003 + A1:2009

Biocompatibility Compliance: ISO 10993, ASTM F 719 and ASTM F 720